What got replaced
Owners who name the part that was replaced mention the fuel pump (34 reports) and the high-pressure pump (7 reports).
Recalls and investigations
4 recalls on the fuel and propulsion cover the 2020 model year. A recall on the same system isn't always the same failure, so read the defect text.
26V-158Mar 17, 2026
Fuel System, Diesel:Delivery:Fuel Pump
Ford Motor Company (Ford) is recalling certain 2020-2022 F-Super Duty F250, F350, F450, F550, 2021-2022 F600, and 2022 F750 vehicles previously repaired incorrectly under recall number 24V957. Biodiesel deposits may form on the pump drivetrain roller components, which could lead to failure of the high pressure fuel pump.
Risk and remedy
Risk: High pressure fuel pump failure can cause a loss of drive power, increasing the risk of a crash.
Remedy: Dealers will update the powertrain control module (PCM) software, free of charge. Owner notification letters were mailed mailed April 7, 2026. Owners may contact Ford customer service at 1-866-436-7332. Ford's number for this recall is 26S17. Vehicle Identification Numbers (VINs) involved in this recall became searchable on NHTSA.gov on March 18, 2026.
24V-957Dec 20, 2024
Fuel System, Diesel:Delivery:Fuel Pump
Ford Motor Company (Ford) is recalling certain 2020-2022 F-Super Duty F250, F350, F450, F550, F600, and 2021-2022 F-650, F750 vehicles. Biodiesel deposits may form on the pump drivetrain roller components, which could lead to failure of the high pressure fuel pump.
Risk and remedy
Risk: High pressure fuel pump failure can cause a loss of drive power, increasing the risk of a crash.
Remedy: Dealers will update the powertrain control module (PCM) and Transmission Control Module (TCM) software, free of charge. Owner notification letters were mailed January 23, 2026. Owners may contact Ford customer service at 1-866-436-7332. Ford's number for this recall is 24S78.
22V-256Apr 14, 2022
Power Train:Automatic Transmission
Ford Motor Company (Ford) is recalling certain 2020 Super Duty F-250, F-350, F-450, and F-550 vehicles equipped with 6.7L diesel engines. A washer within the vehicle's transmission can disintegrate, causing metallic debris to become lodged in the 'Park' mechanism.
Risk and remedy
Risk: Debris lodged within the 'Park' mechanism may prevent the vehicle from achieving or holding 'Park,' increasing the risk of a vehicle rollaway and a crash.
Remedy: Dealers will replace a gearset within the transmission, free of charge. Owner notification letters were mailed on April 19, 2023. Owners may contact Ford customer service at 1-866-436-7332. Ford's number for this recall is 22S22.
20V-365Jun 23, 2020
Power Train:Automatic Transmission:Torque Converter
Ford Motor Company (Ford) is recalling certain 2020 Super-Duty F-250, F-350, and F-550 diesel pickups. The transmission torque converter damper plate was not tempered, resulting in a brittle damper plate that may fracture and cause the engine to stall or require increased brake pedal effort in order to stop the vehicle.
Risk and remedy
Risk: An engine stall or requiring additional braking effort to stop the vehicle can increase the risk of a crash.
Remedy: Ford will notify owners, and dealers will replace the transmission assembly, free of charge. This recall began July 6, 2020. Owners may contact Ford customer service at 1-866-436-7332. Ford's number for this recall is 20S33.
NHTSA investigations into the fuel and propulsion on the F-250 Super Duty
PE24-014opened May 9, 2024
Fuel System, Diesel · model years 2015 to 2021
Sogefi secondary diesel fuel filter leak. Open.
NHTSA summary
The Office of Defect Investigations (ODI) has received 27 complaints alleging diesel fuel leaks due to a fracture in the secondary fuel filter housing in model year (MY) 2015-2021 Ford Motor Company (Ford) F-250, 350, 450, and 550 Super Duty vehicles equipped with 6.7L diesel engines. Of these complaints, 12 describe an engine compartment fire. The proximity of the secondary fuel filter to high heat sources creates a potential for autoignition thermal events and fires. ODI has contacted the vehicle manufacturer, Ford, and the filter manufacturer, Allevard Sogefi USA (Sogefi), and learned that the low-pressure fuel system is capable of a maximum operating pressure of 8.5 Bar, while the secondary fuel filter is only tested to seven (7) Bar during the manufacturing process. Additionally, changes starting in 2022 by both Ford and Sogefi align with a lack of similar complaints on MY 2022 and newer vehicles. ODI is opening this Preliminary Evaluation (PE) to evaluate the severity of the potential problem and to fully assess the potential safety-related problems. To review the ODI reports cited in the Opening Resume ODI Report Identification Number document, go to NHTSA.gov.
EA06-012opened Jun 22, 2006
Engine And Engine Cooling · model years 1997 to 2003
Engine stalling. Closed dec 7, 2007, led to recall 07V-553.
NHTSA summary
IN A DECEMBER 3, 2007 LETTER, FORD ADVISED NHTSA THAT IT WILL CONDUCT A SAFETY RECALL TO REPLACE THE CAM POSITION SENSOR (CPS) IN APPROXIMATELY 1.2 MILLION SUBJECT VEHICLES TO ADDRESS REPORTS OF ENGINE STALLING.A NEW DESIGN CPS WITH IMPROVED PERFORMANCE AND DURABILITY WILL BE INSTALLED AS A REMEDY.OWNER NOTIFICATIONS WILL BEGIN IN DECEMBER 2007. THE SUBJECT VEHICLES ARE DURABLE, FULL-SIZED, MEDIUM DUTY TRUCKS COMMONLY USED FOR COMMERCIAL PURPOSES, RESCUE/EMERGENCY RESPONSE, AND COMMERCIAL OR RECREATIONAL TOWING.CPS FAILURE IS COMPARABLE TO UNEXPECTEDLY TURNING THE KEY OFF SINCE THE SIGNAL IT PRODUCES IS VITAL TO THE ELECTRONIC ENGINE CONTROL SYSTEM.CPS SIGNAL LOSS TERMINATES FUEL INJECTION RESULTING IN AN ENGINE STALL.ONCE STALLED, THE ENGINE MAY RESTART RIGHT AWAY, OR MAY RESTART AFTER A DELAY (TYPICALLY 5 TO 10 MINUTES), OR MAY NOT RESTART AT ALL.IN ADDITION TO EXPOSING THE DRIVER AND OTHER MOTORISTS TO CRASH RISK DUE TO LOSS OF MOTIVE POWER OR VEHICLE DISABLEMENT, ENGINE STALLING ALSO EFFECTS THE POWER ASSISTED STEERING AND BRAKING. THROUGH CONSUMER INTERVIEWS, ODI DETERMINED THAT CPS FAILURES OCCURRED WITHOUT ANY FORM OF WARNING, AT ANY VEHICLE SPEED (50% AT HIGHWAY SPEEDS), AND UNDER ANY DRIVING CONDITION, SUCH AS ACCELERATING.CONSUMERS REPORTED THAT ABOUT A THIRD OF THE VEHICLES FAILED TO RESTART, WITH ANOTHER THIRD REPORTING DELAYED RESTARTING.HALF THE VEHICLES THAT DID RESTART EXPERIENCED ANOTHER STALL ON THE SAME OR A SUBSEQUENT DRIVE CYCLE (BEFORE CPS REPLACEMENT) R
PE06-011opened Feb 27, 2006
Engine And Engine Cooling · model years 1999 to 2001
Engine stalling. Closed jun 23, 2006.
NHTSA summary
THE CAM POSITION SENSOR (CPS) PROVIDES A CRITICAL SIGNAL TO THE SUBJECT VEHICLE (SV) ENGINE MANAGEMENT SYSTEM, THE LOSS OF WHICH RESULTS IN AN ENGINE STALL.DURING PE06-011, FORD STATED IN THEIR RESPONSE TO ODI THAT IT IS CONTINUING TO INVESTIGATE ALLEGATIONS OF CPS RELATED ENGINE STALL AND FURTHER ADVISED THAT AN UPDATE WILL BE PROVIDED UPON COMPLETION OF THE INVESTIGATION.FORD DATA SHOWS THAT 20% OF THE 716,000 SVS ARE EQUIPPED WITH MANUAL TRANSMISSIONS WHICH ARE CAPABLE OF BACK-DRIVING THE ENGINE WHEN A STALL OCCURS; POWER ASSISTED STEERING AND BRAKING ARE NOT LOST DURING ENGINE BACK-DRIVE.FORD DATA ALSO INDICATES THAT BACK-DRIVE OCCURS IN AUTOMATIC TRANSMISSION VEHICLES ABOVE CERTAIN ROAD SPEEDS.THE MANUFACTURER REPORTS NOTED REFERENCE 755 UNIQUE VEHICLES; 2 ARE DUPLICATIVE OF ODI REPORTS.IN ITS REVIEW OF CUSTOMER AND FIELD REPORTS, FORD IDENTIFIED SOME 800 REPORTS ALLEGING ONE OR MORE ENGINE STALLS POTENTIALLY RELATED TO A CPS FAILURE IN THESE 755 VEHICLES (FORD?S ?A? CATEGORY REPORTS).ODI HAS NOT COMPLETED ITS REVIEW OF THESE OR OTHER FORD REPORTS, NOR HAS IT CONFIRMED THIS COUNT.ALL BUT ONE OF THE 9 CRASH ALLEGATIONS APPEAR TO BE MINOR IN NATURE ALTHOUGH ODI IS STILL INVESTIGATING THESE CRASH/INJURY ALLEGATIONS AND WHETHER OR NOT THEY INVOLVE A CPS FAILURE.BASED ON EARLY ASSESSMENT OF THE APPROXIMATELY 166,000 SUBJECT VEHICLE WARRANTY CLAIMS FORD PAID, THERE APPEARS TO BE VARIABILITY IN CLAIM RATES BETWEEN CERTAIN SV PRODUCTION PERIODS; AN EXPLANATION FOR THIS HAS NOT B
DP05-005opened Sep 22, 2005
Engine And Engine Cooling · model years 1997 to 2004
Spark plug ejection from cylinder head. Closed jan 4, 2006.
NHTSA summary
ON SEPTEMBER 6, 2005, ODI RECEIVED A PETITION REQUESTING THAT THE AGENCY INVESTIGATE ALLEGATIONS OF ENGINE SPARK PLUG EJECTION IN CERTAIN MODEL YEAR 1997 THROUGH 2004 FORD VEHICLES WITH TRITON V-8 AND V-10 ENGINES.ODI RECEIVED A TOTAL OF 474 NON-DUPLICATIVE COMPLAINTS ON THE SUBJECT VEHICLES WHERE THE COMPLAINANT, OR THE DEALER REPAIRING THE VEHICLE, REPORTED THAT A SPARK PLUG DETACHED FROM THE CYLINDER AND/OR EJECTED FROM THE ENGINE.AS OF DECEMBER 8, 2005, ODI IS NOT AWARE OF ANY ALLEGATIONS WHERE THE ALLEGED DEFECT RESULTED IN A LOSS OF VEHICLE CONTROL, A CRASH, AN INJURY, OR A FATALITY IN ANY OF THE 10,319,810 SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF ONLY TWO INCIDENTS WHERE THE VEHICLE STALLED WITHOUT RESTART.INFORMATION CONTAINED IN THE ODI CONSUMER COMPLAINTS AND OBTAINED FROM 72 TELEPHONE INTERVIEWS WITH COMPLAINANTS SHOWED THE FOLLOWING:(1) 99% OF THE COMPLAINTS WERE ON MY 1997 TO 2002 SUBJECT VEHICLES.(2) MOST THE COMPLAINANTS REPORTED HEARING A LOUD POP WHILE DRIVING OR UPON STARTING UP THE VEHICLE FOLLOWED BY A LOUD, REPETITIVE CLICKING OR POPPING SOUND.(3) MANY OF THE COMPLAINANTS REPORTED THAT THE POPPING SOUND WAS ACCOMPANIED BY SOME LOSS OF VEHICLE POWER; HOWEVER, IN 99% OF THE INCIDENTS REPORTED, THE VEHICLE DID NOT STALL.IN THE VERY FEW INCIDENTS WHERE THE VEHICLE DID STALL, MOST VEHICLES COULD BE RESTARTED.(4) ONLY A SMALL PERCENTAGE OF THE COMPLAINANTS CITED THAT THEY SMELLED GAS OR A SLIGHT BURNING SMELL WHEN THE INCIDENT OCCURRED.(5) IN ALL BUT A VER
PE04-070opened Oct 7, 2004
Engine And Engine Cooling · model years 2003 to 2004
Engine stalling. Closed feb 15, 2005.
NHTSA summary
TWENTY FIVE OF THE ODI FAILURE REPORTS ARE DUPLICATIVE OF FORD COMPLAINTS.TWENTY ODI REPORTS DO NOT CONTAIN A VIN (AND MAY OR MAY NOT BE DUPLICATIVE OF FORD REPORTS).THE 14 ALLEGED CRASHES AND 2 ALLEGED INJURIES WERE ALL MINOR.SUBMITTED DURING PRELIMINARY EVALUATION (PE) 04-070, FORD'S RESPONSE TO ODI'S INFORMATION REQUEST (IR) LETTER CONTAINED ABOUT 5,000 CONSUMER REPORTS (MORS) AND 8,700 FIELD REPORTS (CQIS).FORD REVIEWED THE COMPLAINTS AND CATEGORIZED THEM.THE MANUFACTURER REPORTS SHOWN ABOVE REPRESENT A COUNT OF UNIQUE VEHICLES THAT FORD CATEGORIZED AS ALLEGEDLY STALLING DUE TO A SUBJECT ENGINE COMPONENT ('A' CATEGORY, SEE FORD'S IR RESPONSE LETTER FOR FURTHER DETAIL); SOME OF THESE VEHICLES RECEIVED MULTIPLE REPORTS.ODI HAS NOT YET CONFIRMED FORD'S CATEGORIZATION OF THESE REPORTS, NOR HAS ODI CONFIRMED FORD'S CATEGORIZATION OF THE REMAINING REPORTS (WHICH FORD STATES DO NOT PERTAIN TO THE ALLEGED DEFECT).FORD SUBMITTED NEARLY 19,000 WARRANTY CLAIMS, MANY OF WHICH INVOLVED CLAIMS FOR A TECHNICAL SERVICE BULLETIN (TSB 04-13-08) AND FIELD SERVICE ACTION (FSA 03B05) WHICH FORD IDENTIFIED AS POTENTIAL REMEDIES FOR STALLING COMPLAINTS.ODI HAS NOT CONFIRMED THAT EITHER OF THESE ARE A REMEDY FOR ENGINE STALLING COMPLAINTS.SEVERAL OTHER DEALER COMMUNICATIONS RELATED TO ENGINE STALL WERE ALSO SUBMITTED AS WELL AS OVER 50 PRODUCT MODIFICATIONS, 15 OF WHICH INVOLVE REVISIONS TO THE SOFTWARE FOR THE ELECTRONIC ENGINE CONTROL UNIT.FURTHER INVESTIGATION IS REQUIRED AND ODI IS UPGRADING
RQ98-008opened May 29, 1998
Fuel system · model years 1991
Ford f-series dual fuel tank leakage. Closed nov 4, 1999, led to recall 93V-125.
NHTSA summary
THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS NEEDED.THIS INVESTIGATION IS UPGRADED TO EA99-032.CLICK ON DOCUMENT SEARCH BUTTON FOR ADDITIONAL INFORMATION.
EA95-012opened Mar 31, 1995
Transmission and drivetrain · model years 1992 to 1994
Failure of serpentine belt. Closed may 28, 1996, led to recall 96I-003.
NHTSA summary
AN ENGINEERING ANALYSIS CLOSING REPORT IS INCLUDED.
PE94-087opened Nov 18, 1994
Transmission and drivetrain · model years 1994
Trns oil cooler line fails. Closed mar 31, 1995.
NHTSA summary
FORD HAS ACKNOWLEDGED A SERIOUS PROBLEM WITH THE ACCESSORY DRIVE BELT SYSTEM (SERPENTINE BELT) IN THE SUBJECT VEHICLES.SEVERAL SERVICE BULLETINS HAVE BEEN ISSUED TO ADDRESS CONCERNS RELATED TO BELT TRACKING OR WEAR.FORD MAINTAINS THAT THE SUBJECT CONDITION DOES NOT PRESENT AN UNREASONABLE RISK TO HIGHWAY SAFETY, ARGUING THAT THE LOW INCIDENCE OF FAILURES ALLEGING SAFETY CONSEQUENCES (I.E., FIRES, FLUID LEAKS, AND/OR ACCIDENTS) IS STRONG EVIDENCE IN SUPPORT OF THIS CLAIM.FORD HAS INDICATED RECEIPT OF 4,445 FIELD REPORTS AND 46891 WARRANTY CLAIMS CONCERNING THE SUBJECT CONDITION. FORD MAINTAINS THAT THE LOW NUMBER OF REPORTED HOSE RUPTURES AND/OR FIRES, RELATIVE TO TOTAL BELT FAILURES, SHOWS THAT THE PROBLEM IS A DURABILITY CONCERN THAT PRESENTS VERY LITTLE RISK TO MOTOR VEHICLE SAFETY.FORD INTENDS TO ADDRESS THE PROBLEMIN A SERVICE BULLETIN SCHEDULED FOR PUBLICATION THE WEEK OF MARCH 13, 1995.ODI HAS RECEIVED SEVERAL CLAIMS ALLEGING THAT INCIDENTS OF BELT FAILURE ARE CAUSING COLLATERAL DAMAGE TO ADJACENT FLUID SYSTEMS (E.G., POWER STEERING HOSE, COOLANT HOSE, AND AUTOMATIC TRANSMISSION OIL COOLER HOSE).RELEASE OF THESE FLUIDS WITHIN THE ENGINE COMPARTMENT MAY RESULT IN A VEHICLE FIRE, IF EXPOSED TO A SUFFICIENTLY HOT SURFACE AREA.THE AUTOIGNITION TEMPERATURE FOR TRANSMISSION OIL MAY BE AS LOW AS 300 C (570 F), WHILE POWER STEERING FLUID AND ENGINE COOLANT ARE GENERALLY HARDER TO IGNITE (CLOSER TO 500 DEGREE C (900 DEGREEF)).DAMAGE TO BATTERY CABLE INSULATION HAS ALSO BEEN ALLE
EA93-022opened Jul 30, 1993
Engine And Engine Cooling · model years 1991 to 1992
Idle air spd ctrl vlv malf. Closed aug 31, 1994.
NHTSA summary
There is no summary currently available
PE93-010opened Mar 2, 1993
Engine And Engine Cooling · model years 1991 to 1992
Idle air spd ctrl vlv malf. Closed jul 30, 1993.
NHTSA summary
There is no summary currently available
PE92-055opened Jun 24, 1992
Engine And Engine Cooling · model years 1992
Engine compartment fires. Closed aug 20, 1992, led to recall 92V-112.
NHTSA summary
There is no summary currently available
PE91-064opened Apr 9, 1991
Transmission and drivetrain · model years 1991
Transmission fluid fires. Closed jul 5, 1991.
NHTSA summary
There is no summary currently available
When it happens
The middle half of failures fell between 69,000 and 121,000 miles, from the 22 reports that gave a mileage.